Between your panels, inverter and home wiring sit two important boxes: the DCDB (DC Distribution Box) and the ACDB (AC Distribution Box). They protect your system from faults and surges and allow safe isolation for maintenance.
DCDB — on the panel side
The DCDB sits between the solar panels and the inverter's DC input. It typically contains:
- DC fuses for each string — protect cables from reverse current/overcurrent (as per design)
- DC isolator / disconnector — safely disconnects panels from the inverter
- DC SPD (Surge Protection Device) — diverts lightning-induced surges to earth
ACDB — on the grid side
The ACDB sits between the inverter's AC output and your main distribution board. It typically contains:
- MCB or MCCB — overload and short-circuit protection
- RCCB / RCBO (as per design) — protection against earth leakage
- AC SPD — protects against surges from the grid side
- Sometimes an energy meter or indicator lamps
Why DC protection is special
DC current doesn't pass through zero like AC, so DC arcs are harder to extinguish. Only DC-rated fuses, isolators and SPDs should be used on the DC side. Using AC components on DC circuits is dangerous.
How to judge quality
- Rated voltage of DC components matches system voltage
- Branded fuses, isolators and SPDs with proper certifications
- IP-rated enclosure (dust and water protection)
- Proper cable glands and neat internal wiring
- Earth bar connected to the earthing system
- Clear labelling
Common shortcuts to avoid
- ❌ No SPDs, or AC SPDs used on the DC side
- ❌ No string fuses where design requires them
- ❌ Plastic boxes without proper glands in direct sun
- ❌ Undersized MCBs or loose terminals

Maintenance
SPDs have an indicator window — green means OK, red means replace. Check it periodically, especially after thunderstorms. See our maintenance checklist.
Frequently asked questions
Can I reset a tripped MCB in the ACDB myself?
Yes, once. If it trips repeatedly, call a technician.
Should the DCDB be indoors?
It can be outdoors if properly IP-rated, but shade and protection from direct rain help.
What is a DC isolator used for?
To safely disconnect panels from the inverter for maintenance.